SERVICES

Accredited examinations

Testing laboratory

Eurosignal, a.s. operates two test laboratories under the name ZTL EUROSIGNAL – the Electromagnetic Compatibility Laboratory (EMC) and the Climatic Testing Laboratory (KLIMA).

Both laboratories have been accredited by the Czech Institute for Accreditation (CIA) since 2010 and 2012 respectively, currently in accordance with EN ISO/IEC 17025: 2018. The accreditation certificate can be downloaded here.

The laboratories can be found in the premises of the Science and Technology Park in Mstětice on the eastern outskirts of Prague near the railway station Mstětice (located on the line Prague – Lysá nad Labem), see Contacts.

EMC Laboratory

In the Electromagnetic Compatibility (EMC) laboratory we perform tests of electromagnetic interference (EMI) and electromagnetic immunity (EMS) of various electrical, electronic and other products or equipment, both production, i.e. already finished products, as well as prototypes or development samples, depending on the customer’s requirements.

The EMC Laboratory offers:

Accredited examinations

The EMC laboratory shall perform the tests according to the standards listed in the following table, always according to the latest valid version/edition of the standard. The annex to the accreditation certificate can be downloaded here.

EMI and EMS tests

standard

Accredited examination

Testing to tribal standards

Emission by cover (30 – 6000 MHz)

CSN EN 55032
CSN EN 55011
CSN EN IEC 61000-6-8

Yes

Emission to ports (150 kHz – 30MHz)

Electrostatic discharge resistance – ESD

EN 61000-4-2

Yes

Resistance to RF field

EN 61000-4-3

Yes

Resistance to fast transients – EFT

EN 61000-4-4

Yes

Shock resistance – SURGE

EN 61000-4-5

Yes

Resistance to conducted interference

EN 61000-4-6

Yes

Resistance to interruptions and changes in supply voltage – DIP

EN 61000-4-11 EN 61000-4-29

Yes

Tests according to product standards

Products for the home environment

CSN EN IEC 61000-6-1
CSN EN IEC 61000-6-3

YES

Products for industrial environments

CSN EN IEC 61000-6-2
CSN EN IEC 61000-6-4

YES

Electrical measuring, control and laboratory equipment

EN 61326-1

YES

Railway vehicles

EN 50121-3-2

YES

Railway signalling and communication equipment

EN 50121-4

YES

Non-accredited examinations

The EMC laboratory also offers tests that our testers can perform, but for economic reasons or because of low interest, they were not included in the current accreditation. These include:

  • Magnetic field pulses EN 61000-4-9
  • Damped sine wave EN 61000-4-12
  • Gas detection equipment EN 50270
  • Road traffic signalling systems EN 50293
  • IT equipment EN 55024
  • MME equipment EN 55035
  • El. Luminaires EN IEC 55015
  • Marine equipment DNVGL-CG-0339
  • Telecommunications Equipment FCC Title 47, Part 15.107 and Part 15.109

Development and verification tests

In the case where the device (sample) under test:

  • is not yet ready for comprehensive EMC testing,
  • has several variants and the best one from the EMC point of view should be compared,
  • failed EMC test at another test facility and we need to find out why and fix this deficiency,
  • Requires one test to be repeated X times to adjust/tweak sensitivity/increase resistance,
  • is to meet specific EMC requirements that are different from those accredited by ZTL EUROSIGNAL and for which ZTL EUROSIGNAL has assessed that our instruments can be adapted to these different requirements,

the EMC laboratory offers so-called development and verification tests. These always take place in the presence of the customer, who primarily operates his test sample, if necessary adjusts, programs or otherwise modifies it (we also offer a modest space for soldering) and the EMC laboratory technician repeatedly measures the parameter or performs the test until the problem is solved.

From the tests, the customer takes away both the EMC-compliant sample (if the “EMC problem” can be solved) and the tester printouts that were generated during the tests (i.e. prints or PDF or TXT files).

Please note: the rules of the accreditation do not allow ZTL EUROSIGNAL to measure samples that have passed the development tests here. The final measurement of such samples must be arranged by the customer at another testing facility.

Measuring capability (for accredited tests):

Test sample (EUT)

  • Max. height: 150 cm (standing) or 70 cm (table)
  • Max. width/depth: 90 cm/90 cm
  • Max weight: 350 kg (standing) or 50 kg (table)
  • Power supply AC (1f): 50 – 300 V / 14 – 400 Hz, typically 240 V / 50 Hz
  • Power supply AC (3f): 3x 400 V / 50 Hz
  • Power supply DC: 4x 0 – 30 V /5 A (voltages or currents can be added)

EMI cover:

  • Workstation:EMC chamber with a measuring distance of 3m
  • Frequency range: 30 – 6000 MHz

EMI to the ports:

  • Frequency range
  • AC power port: 9 kHz – 30 MHz, typically 150 kHz – 30 MHz
  • Data/control ports (ETH, RS485, …): 150 kHz – 30 MHz

ESD:

  • contact: 2 – 10 kV
  • air direct: 2 – 15 kV
  • air indirect: 2 – 15 kV

VF field:

  • 80 – 1000 MHz: field strength: 1 – 20 V/m (AM) or 1 – 40 V/m (PM)
  • 1 – 6 GHz: field strength: 1 – 10 V/m (AM) or 1 – 20 V/m (PM)

EFT:

  • Waveform: 5/50 ns
  • Test voltage: 250 V – 4.4 kV
  • Pulse repetition rate: 1 kHz – 1 MHz, typically 15 kHz and 100 kHz

SURGE:

  • Waveform: 1.2/50 µs
  • Test voltage: 220 V – 4.1 kV

Guided interference:

  • Frequency range: 150 kHz – 230MHz, typically 150 kHz -80 MHz
  • Test levels: 1 – 15 V (AM) or 1 – 30 V (PM)

Climatic Testing Laboratory

The Climate Testing Laboratory (KLIMA) performs:

  • exposure of the test samples to a specific environment, namely temperature and/or humidity. For this purpose, it is equipped with two climate chambers:
    • Small chamber: internal dimensions 1 x 1 x 1 m
    • Large chamber: internal dimensions 3 x 3 x 2.6m (w x d x h)
  • electrical (insulation) strength tests, where KLIMA takes advantage of the possibility to expose the tested sample to high humidity before the actual electrical strength test.

Climatic testing is performed when assessing the ability of samples to survive or operate in prescribed climatic conditions, such as transport conditions where the sample is switched off for the duration of the test, or when placing samples outdoors or in otherwise challenging climatic environments (deep freeze, frequent rain, tropical conditions, etc.) where the sample may be first cooled (or tempered) and then switched on or on for the duration of the test.

Accredited examinations

The KLIMA laboratory carries out tests according to the standards listed in the following table, always according to the latest valid version/edition of the standard. The annex to the accreditation certificate can be downloaded here.

EMI and EMS tests

standard

Accredited examination

Environmental tests

Cold to -40°C

EN 60068-2-1

Yes

Dry heat up to +100°C

EN 60068-2-2

Yes

Moist heat constant

EN 60068-2-78

Yes

Moist heat cyclic

EN 60068-2-30

Yes

Composite temperature and humidity cyclic test

EN 60068-2-38

Yes

Electrical strength measurement

Electrical (insulation) strength

EN 60335-1

EN 61010-1

YES

Non-accredited examinations

Non-accredited tests are carried out by KLIMA laboratory in case the customer requires a specific temperature course that does not correspond to the courses in accredited standards (and the parameters of our climate chambers allow such tests), or does not require a test report to be drawn up from the measurements.

Measuring ability

Limiting parameters of the generated environment in climates:

  • Temperature: -40°C to +100°C, typically -35°C to +70°C (+/- 1°C)
  • Relative humidity: unregulated, possibly up to 96% RH (+/- 3% RH)

Temperature and relative humidity

The temperature (T) and relative humidity (RH) can be continuously controlled in both chambers and the test sample can be made up of different successive sections with different temperatures and associated humidities.

Duration of the test

Theoretically, the test time is not limited, the test can run for infinite hours, but in practice we always try to divide the test into sections that do not exceed the working week, i.e. about 105 hours of net running of the climacompartment.

Test sample

The test specimen can be any non-perishable device or product (e.g. food, organic substances, explosives, etc.), non-emitting (e.g. combustion engines) or products that require a medium (water, nitrogen, etc.), ideally electrical, electronic or mechanical equipment.

The size of the sample must be such that it fits with sufficient margin for air to circulate into one of the climatic chambers, with the passage width for transporting the sample to the laboratory limited to 1,5 m. Larger samples can be assembled in the chamber from smaller, more easily transportable parts.

The sample weight for placement in the small chamber is max. 20 kg, for placement in the large chamber max. 300 kg.

Sample power supply

The sample can be powered during the test from the 240 V or 3 x 400 V public mains.

Monitoring the sample during the test

  • Up to 8 temperature probes can be placed on the surface of the sample under test or inside the sample and these temperatures can be monitored during the test and the measured values registered in the data logger.
  • Up to 8 DC voltages (-6 to 25 V or 4 to 60 V) can be monitored or resistance or current measured at a selected sample location using the additional inputs of this datalogger,
  • The current draw (power) of the sample can be monitored
  • In the temperature range of approx. -10°C – +70°C, the sample can be monitored with a camera
  • In addition, suitable customer tracking equipment can be placed outside the chamber and connected to the test sample

Results

Accredited examinations are always concluded with an Examination Report (ER). This is issued in Czech and at the customer’s request also in English. We do not issue English PoZ without Czech PoZ.

The results of non-accredited tests can, if the customer is interested, also be entered in the PoZ, but only with the designation “non-accredited”.

Test reports are not issued for developmental tests.

Certificates

Standards and accreditations

A current list of standards is provided in the scope of accreditation.